4.2 The Dental-Sealant-Application Process

Step 7: Final Treatment of Surface

  • To remove the oxygen-inhibited layer and reduce the possibility of unpolymerized monomer remaining on the tooth, wipe the surface of the tooth with a cotton roll or cotton applicator before having the child thoroughly rinse with water.